DRN-FP
/ DRX-FP
Software Selectable Input Types
and Ranges
Unipolar/Bipolar 400 mV to 10 Vdc,
0-20 mA dc
11-14-Bit Resolution
10 Vdc Excitation
0.2% FS Accuracy
1800 Volts Isolation
250 Vac/1 Min. Input Overvoltage Protection
(Voltage Input Only)
|
DIN
RAIL MOUNT
|
The INFINITY®
signal conditioners provide high accuracy isolated measurement of frequency
and pulse signals. For maximum flexibility, the units feature user configurable
input types which are fully field scalable. Two models are available,
the DRN-FP which provides an analog output that is proportional to the
input signal and the DRX-FP which uses a digital RS-485 communication
link. Both models measure frequency signals up to 50 kHz and can count
up to two million pulses. The DRX-FP and DRN-FP are compatible with a
wide variety of transducers including proximity, switch, magnetic pickup,
NAMUR, contact closure and open collector transducers.
The output of DRN-FP can be user set for 0-10 V, 4-20 mA or 0-20
mA. Input scaling and configuration of other operating parameters is accomplished
by connecting to a standard RS232 port of a personal computer and using
the DRN-CONFIG, Windows-based setup software. Once configured the settings
may be stored in non-volatile memory and the unit disconnected from the
PC.
The DRX-FP is a digital signal conditioner which communicates over
an RS-485 communication link. Up to 32 modules may be connected to a single
RS-485 port stretching up to 4,000 ft. Through the use of RS-485 repeaters,
additional modules may be used and further transmission distances are
achievable.
SPECIFICATIONS
Accuracy at 25░C: ▒0.02% FS for frequency,
▒0.01% FS for pulse input
Resolution: 15 to 19 Bit
Max Count: 999,999
Power Consumption: 2.4 W (100 mA @ 24 Vdc) without excitation,
3 W (125 mA @ 24 Vdc) with excitation
Input Ranges: Frequency from 200 Hz to 50 kHz, pulse from 20,000
to 200,000,000 (200M) pulses full scale
DRX Output: 2-wire (half duplex) RS-485
DRN Output: 0 to 10 V @ 10 mA max; 0 to 20 mA or 4 to 20 mA
To
Order (Specify Model No.) Prices
Shown in U.S. Dollars
Model No.
|
Description
|
Price
|
DRX-FP
|
Digital
signal conditioner with RS-485 output for process signals |
$250
|
|
Signal
conditioner with analog output for process signals |
$295
|
Each unit supplied
with complete operatorÆs manual.
Ordering
Example: DRX-FP
digital signal conditioner with RS-485 output for process signals ($250),
plus DRN-PS-750 power supply, 115 Vac input, 24 Vdc output @ 750 mA ($130),
$250 + 130 = $380.
ACCESSORIES
Model No.
|
Description
|
Price
|
DRN-CONFIG-(*)
|
Setup
software for DRN series modules, includes serial connection cable
|
$100
|
DRN-PS-750
|
Power
supply, 115 Vac input, 24 Vdc output @ 750 mA |
$130
|
DRN-PS-1000
|
Power
supply, 95-240 Vac input, 24 Vdc output @ 1 amp |
$150
|
CAT-285
|
Bi-directional
RS-232-RS-485 converter for DRX series |
$148
|
*Specify
"9" for 9-pin
or "25" for
25-pin serial cable.
|